Chống cháy nổ Fluke 568 Ex1 Chống cháy nổ Fluke 568 Ex1
  • The Fluke 568 Ex Intrinsically Safe Infrared Thermometer is the one product you can use in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments anywhere in the world. Whether you work in petroleum, chemical, oil and gas, or pharmaceutical environments, the 568 Ex allows you to carry the most trusted name in test tools into most Ex rated areas all around the globe.
Fluke-568-Ex1 Chống cháy nổ 0 VND Số lượng: 0 cái


  •  
  • Chống cháy nổ Fluke 568 Ex1

  • Đăng ngày 07-10-2015 10:52:09 AM - 6093 Lượt xem
  • Giá bán: Liên hệ

    • The Fluke 568 Ex Intrinsically Safe Infrared Thermometer is the one product you can use in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments anywhere in the world. Whether you work in petroleum, chemical, oil and gas, or pharmaceutical environments, the 568 Ex allows you to carry the most trusted name in test tools into most Ex rated areas all around the globe.


Số lượng
With a rugged, easy-to-use, ergonomic design, the Fluke 568 can stand up to tough industrial, electrical, and mechanical environments.
  • Meets intrinsically safe certifications in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments from recognized safety agencies around the world
  • Measure -40 °C to 800 °C /-40 °F to 1472 °F
  • Conductive Case for carrying the IR thermometer safely into hazardous area
  • Easily access advanced features with the soft-key buttons and graphical display
  • Measure small objects from further away, with a distance-to-spot ratio of 50:1
  • Compatible with mini-connector K-type thermocouple (KTC) probe
  • Confidently measure a wide variety of surfaces with the adjustable emissivity feature, including a built-in material table
  • Capture up to 99 points of data
  • Confidently troubleshoot equipment with ± 1 % measurement accuracy
  • Versatile interface with five languages from which to choose
  • Two-year warranty
Specifications
Infrared temperature range -40 °C to 800 °C 
(-40 °F to 1472 °F)
Infrared accuracy < 0 °C (32 °F): ± (1.0 °C (± 2.0 °F) + 0.1°/1 °C or °F);
> 0 °C (32 °F):  ± 1 % or  ± 1.0 °C (± 2.0 °F), whichever is greater
Display resolution 0.1 °C / 0.1 °F
Infrared spectral response 8 µm to 14 µm
Infrared response time < 500 ms
Thermocouple type-k input temperature range -270 °C to 1372 °C (-454 °F to 2501 °F)
Thermocouple type-k input accuracy <-40 °C: ±(1 °C + 0.2 °/1 °C)
≥-40 °C: ±1 % or 1 °C, whichever is greater <-40 °F: ±(2 °F + 0.2 °/1 °F)
≥-40 °F: ±1 % or 2 °F, whichever is greater
D:S (distance to measurement spot size) 50:1
Laser sighting Single-point laser
Minimum spot size 19 mm (0.75 in)
Emissivity adjustment By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
Data storage 99 points
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Display Dot matrix with function menus
Backlight Two levels, normal and extra bright for darker environments
Trigger lock Yes
Switchable celsius and fahrenheit Yes
Power 2 AAA/LR03 type-approved batteries (For a list of type-approved batteries, refer to Product Safety Instructions.)
Battery life 4 hours with laser and backlight on; 
100 hours with laser and backlight off, at 100 % duty cycle
Operating temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage temperature -20 °C to 60 °C (-40 °F to 140 °F)
Bead thermocouple type-k range -40 °C to 260 °C (-40 °F to 500 °F)
Bead thermocouple type-k accuracy ± 1.1 °C (2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F), 
typically within 1.1 °C (2.0 °F) from -40 °C to 0 °C (-40 °F to 32 °F)
 
Safety Certifications
Agency Safety Rating
ATEX/ IECEx 
 
Zone 1 and 2
IECEx EPS 13.0006X
Ex ia IIC T4 Gb
0°C ≤ Ta ≤ 50°C
EPS 13 ATEX 1.525 X
II 2G Ex ia IIC T4 Gb
NEC-500 / NEC-505   
Class I Division 1 and 2
Class I, Division 1, Groups ABCD T4
Class I, Division 2, Groups ABCD T4 
Class I, Zone 1, AEx ia IIC T4
Ex ia IIC T4  
0°C ≤ Ta ≤ 50°C
GOST  
Zone 1 and 2
POCC DE.ГБ05.B
Ex ia IIC T4 Gb X
ОТ 0°C ДО +50°C        
EPS 13 ATEX 1 525 X
II 2G Ex ia IIC T4 Gb
0°C ≤ Ta ≤ 50°C 
PCEC   
Zone 1 and 2 
PCEC
Ex ia IIC T4 Gb
CE13.  
EPS 13 ATEX 1 525 X
II 2G Ex ia IIC T4 Gb
0°C ≤ Ta ≤ 50°C  
INMETRO   
Zone 1 and 2
IEx 13.0122X
Ex ia IIC T4 Gb
EPS 13 ATEX 1 525 X
II 2G Ex ia IIC T4 Gb
0°C ≤ Ta ≤ 50°C 
662.38 KB