Fluke 726 Precision Multifunction Process Calibrator Fluke 726 Precision Multifunction Process Calibrator The Fluke 726 offers best accuracy and performance in a multifunction process calibrator. Fluke multifunction calibration tools designed to calibrate almost anything. These calibration tools source and measure almost all process parameters. P000055 Ma Loop Calibrators 0 VND Quantity: 1 Cái


  •  
  • Fluke 726 Precision Multifunction Process Calibrator

  • Post on 22-09-2015 02:24:37 PM - 1011 Views
  • Price: Contact

  • The Fluke 726 offers best accuracy and performance in a multifunction process calibrator. Fluke multifunction calibration tools designed to calibrate almost anything. These calibration tools source and measure almost all process parameters.


Quantity

Get More Calibration Power

The Fluke 726 Precision Multifunction Process Calibrator is designed specifically for the Process industry with broad workload coverage, calibration power and unsurpassed accuracy in mind. The 726 measures and sources almost all process parameters and can calibrate almost anything. The 726 will also interpret results without the help of a calculator and store measurement data for later analysis.

Need an intrinsically safe rating in your calibrator? Consider the Fluke 725Ex Intrinsically Safe Multifunction Process Calibrator.

Want documenting and HART communication built into your calibrator? Consider the Fluke 754 Documenting Process Calibrator with HART.

 

Measurement Accuracy
Voltage DC 30.000 V 0.01% + 2 mV (upper display)
20.000 V 0.01% + 2 mV (lower display)
90.00 mV 0.01% + 10 μV
-10.00 mV to 75.00 mV 0.025% + 1 count (via TC connector)
Current DC 24.000 mA 0.01%+ 2 mA
Resistance 0.0 to 4000.0 Ω ± 0.015%
Frequency 2.0 to 1000.0 CPM 0.05% + 0.1 cpm
1.0 to 1000.0 Hz 0.05% + 0.1 Hz
1.00 to 15.00 kHz 0.05% + 0.01 kHz
Sensitivity 1 V peak-to-peak-minimum
Pressure

Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.

Source Accuracy
Voltage DC 100.00 mV 0.01% + 10 μV
20.000 V 0.01% + 2 mV
-10.00 mV to 75.00 mV 0.025% + 1 count (via TC connector)
Current DC 24.000 mA (Source) 0.01% + 2 μA
24.000 mA (Simulate) 0.01% + 2 μA
Resistance Range, accuracy (percent of reading + floor) and excitation current 5 to 400 Ω, 0.015% + 0.1 Ω, 0.1 to 0.5 mA
5 to 400 Ω, 0.015% + 0.05 Ω, 0.5 to 3 mA
400 to 1500 Ω, 0.015% + 0.5 Ω, 0.05 to 0.8 mA
1500 to 4000 Ω, 0.015% + 0.5 Ω, 0.05 to 0.4 mA
Frequency 2.0 to 1000.0 CPM 0.05%
1.0 to 1000.0 Hz 0.05%
1.0 to 10.0 kHz 0.25%
10.0 to 15.0 kHz 0.5%
Waveform 5 V p-p squarewave, -0.1 V offset
RTDs and Thermocouples
Measure and source accuracy Cu10 1.8°C
NI-120 0.15°C
PT-100 (385) 0.45°C
PT-100 (392) 0.35°C
PT-100 (391-JIS) 0.35°C
PT-200 (385) 0.95°C
PT-500 (385) 0.55°C
PT-1000 (385) 0.35°C
RTD Resolution 0.01°C (0.01°F)
Cu10.01 C 0.1°C (0.1°F)
J 0.4°C
K 0.5°C
T 0.4°C
E 0.4°C
R 1.4°C
S 1.4°C
B 1.4°C
L 0.45°C
U 0.45°C
N 0.6°C
XK 0.4°C
BP 1.1°C
TC Resolution J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
Specifications
Ramp functions Source functions Voltage, current, resistance, frequency, temperature
Ramps Slow ramp, Fast ramp, 25% step-ramp
Loop power function Voltage 24 V
Accuracy 10%
Maximum current 22 mA, short circuit protected
Step functions Source functions Voltage, current, resistance, frequency, temperature
Steps 25% of range, 100% of range
Environmental Specifications
Operating temperature -10°C to +55°C
Storage temperature -20°C to +71°C
Operating altitude 3000 m
Safety Specifications
Agency approvals EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992
Mechanical and General Specifications
Size 200 x 96 x 47 mm (7.9 x 3.8 x 1.9 in)
Weight 650 g (23 oz)
Batteries 4 AA alkaline batteries
Battery replacement Separate battery compartment, accessible without breaking calibration seal
Side port connections Pressure module connector, also used for remote real-time programming
     

 