Fluke FoodPro Plus Infrared Food Thermometer Fluke FoodPro Plus Infrared Food Thermometer Infrared Food Thermometer - Fluke FoodPro pocket infrared thermometers provide the food service industry with contact and non-contact temperature measurements. P000253 Thermometers 0 VND Quantity: 1 Cái


  •  

Quantity
  • Fluke brings its test and measurement equipment expertise to the foodservice industry with contact and non-contact temperature measurement solutions. The Fluke FoodPro Plus thermometer provides a complete temperature measurement and monitoring solution for foodservice professionals. It includes one useful temperature inspection tool, which is designed to enable foodservice professionals to quickly and accurately measure food product temperatures and to help detect potential food safety problems.

    The Fluke FoodPro Plus combines the same infrared surface temperature scanner, as well as a probe thermometer and integrated countdown timer for complete inspections of food temperatures and monitoring cooking and cooling intervals.

    The Fluke FoodPro Plus thermometer is hand-washable and features unique HACCP check lights, which immediately indicate safe or potentially unsafe holding temperatures with either green or red lights.

    Useful applications

    • Receiving: Use FoodPro Plus thermometer to quickly verify proper temperatures of food products at the point of delivery as recommended by your HACCP program.
    • Food holding: Easily monitor hot and cold food holding. HACCP check lights provide instant recognition of safe/unsafe temperatures.
    • Inspection: Conduct food line inspections daily to ensure compliance with local food temperature monitoring requirements.
    • Equipment Calibration: Verify proper operating temperature of coolers, freezers, grills, fryers, warmers, as well as hot and cold storage units to avoid inconsistent food service, costly spoilage and to allow quicker response, reducing equipment repair costs.
    • Dining room: Easily verify temperatures in every aspect of food serving to ensure safety, enhance quality and reduce waste.
Infrared Specifications
Temperature -35°C to 275°C
Accuracy (Assumes ambient operating temperature of 23°C ±2°)
Between 0°C and 65°C: ±1°C
Below 0°C: ±1° ±0.1 degree/degree
Above 65°C: ±1.5% of reading
Response time < 500 ms after initial reading
Spectral response 8-14 microns
Emissivity Pre-set for foodservice applications
Distance to spot size/Optical resolution (D:S) 2.5:1 @ 90% energy, typical
Typical working range (target illumination) ≈ 25 mm to 250 mm
Minimum target size 12 mm ø
Illumination to IR channel offset 13 mm
Probe Specifications
Temperature -40°C to 200°C
Accuracy (Assumes ambient operating temperature of 23°C ±2°)
Between –5°C and 65°C: ±0.5°C
Below –5°C: ±1°C
Above 65°C: ±1% of reading
Response time 7-8 seconds (3 time constants)
Probe dimensions Diameter: 3.0 mm
Length: 90 mm
Sensor type Thin-film platinum, class A, Resistance
Thermal device (RTD)
Operational Specifications
Repeatability Within accuracy specifications of the unit
Ambient operating range 0°C to 50°C
Relative humidity 90% (±5%) RH non condensing @ 30°C
Storage temperature -20°C to 60°C
Weight 150 g (with battery)
Dimensions 165 x 32 x 50 mm
Power, battery life 9 V alkaline
Battery life Alkaline, 10 hours minimum @ 23°C
Target illumination High brightness LED
Display resolution 4 digits, 0.1°C
Displayhold (7seconds) Yes
LCD backlit display Yes
Temperature display 4 digits, 0.1°C resolution
Maximum temperature displayed Yes
Timer Yes
Environmental data IP54 sealing (hand-washable, non-submersible)
Other Specifications (both)
Calibration certificate Calibration accuracy with NIST and DKD traceability
Standards Conforms to EN 61236-1 Electromagnetic Emissions and Susceptibility, EN 6101-1 General Safety, Sealing IP54 (hand washable, non-submersible)
Certifications CE NSF
Warranty 2 years
Options/Accessories Replacement probe
At calibration geometry of 279 mm with a 140 mm diameter, 0.97 emissivity blackbody. Specifications subject to change without notice.
     

 