Fluke Calibration 9103/9140/9141 Field Dry-Well Fluke Calibration 9103/9140/9141 Field Dry-Well If you’ve been using dry-well calibrators for field work, you know there’s a lot more to a dry-well than its temperature range and stability. Size, weight, speed, convenience, and software are also significant. P000291 Temperature Calibrators 0 VND Quantity: 1 Cái


  •  
  • Fluke Calibration 9103/9140/9141 Field Dry-Well

  • Post on 22-09-2015 11:48:20 PM - 1088 Views
  • Price: Contact

  • If you’ve been using dry-well calibrators for field work, you know there’s a lot more to a dry-well than its temperature range and stability. Size, weight, speed, convenience, and software are also significant.


Quantity
  • Great performance in portable instruments

    • Lightweight and very portable
    • Accuracy to ±0.25°C
    • RS-232 and Interface-it software included
    • Easy to recalibrate

    If you’ve been using dry-well calibrators for field work, you know there’s a lot more to a dry-well than its temperature range and stability. Size, weight, speed, convenience, and software are also significant.

    Field dry-wells need to be portable, flexible, and suitable for high-volume calibrations or certifications. If they’re not, you’ll soon forget about the great stuff the sales rep told you and realize what you’ve really bought.

    At Hart Scientific, we use dry-wells every day in our manufacturing and calibration work, and we know what makes a dry-well easy and productive to use—which is exactly how users describe our series of field dry-wells. These dry-wells work for you instead of the other way around.

    • Specifications 9103 9140 9141
      Range –25°C to 140°C
      (–13°F to 284°F)
      at 23°C ambient
      35°C to 350°C
      (95°F to 662°F)
      50°C to 650°C
      (122°F to 1202°F)
      Accuracy ±0.25°C (holes greater than 1/4" [6.35mm]: ±1°C) ±0.5°C (holes greater than 1/4" [6.35mm]: ±1°C) ±0.5°C to 400°C; ±1.0°C to 650°C
      (holes greater than 6.35 mm: ±2°C)
      Stability ±0.02°C at –25°C
      ±0.04°C at 140°C
      ±0.03°C at 50°C
      ±0.05°C at 350°C
      ±0.05°C at 100°C
      ±0.12°C at 500°C
      ±0.12°C at 650°C
      Well-to-well uniformity ±0.1°C between similarly sized wells ±0.1°C with similarly sized wells ±0.1°C below 400°C, ±0.5°C above 400°C with similarly sized wells
      Heating times 18 minutes from ambient to 140°C 12 minutes from ambient to 350°C 12 minutes from ambient to 650°C
      Cooling times 20 minutes from ambient to –25°C 15 minutes from 350°C to 100°C 25 minutes from 650°C to 100°C
      Stabilization time 7 minutes 7 minutes 7 minutes
      Immersion depth 124 mm (4.875 in) 124 mm (4.875 in) 124 mm (4.875 in)
      Inserts Insert A, B, C, or D included (specify when ordering)
      Outside insert dimensions 31.8 mm dia. x 124 mm (1.25 x 4.88 in) 28.5 mm dia. x 124 mm (1.12 x 4.88 in)
      Computer interface RS-232 included with free Interface-it software (Model 9930)
      Power 115 V AC (±10%), 1.3 A or 230 V AC (±10%), 0.7 A, switchable, 50/60 Hz, 150 W 115 V AC (±10%), 4.4 A or 230 V AC (±10%), 2.2 A, switchable, 50/60 Hz, 500 W 115 V AC (±10%), 8.8 A or 230 V AC (±10%), 4.4 A, switchable, 50/60 Hz, 1000 W
      Size (W x H x D) 143 x 261 x 245 mm
      (5.63 x 10.25 x 9.63 in)
      152 x 86 x 197 mm
      (6 x 3.375 x 7.75 in)
      109 x 236 x 185 mm
      (4.3 x 9.3 x 7.3 in)
      Weight 5.7 kg (12 lb) 2.7 kg (6 lb) 3.6 kg (8 lb)
      NIST-traceable certificate Data at –25°C, 0°C, 25°C, 50°C, 75°C, 100°C, and 140° Data at 50°C, 100°C, 150°C, 200°C, 250°C, 300°C, and 350°C Data at 100°C, 200°C, 300°C, 400°C, 500°C, and 600°C
     

 