Fluke 9132/9133 Portable Infrared Calibrator Fluke 9132/9133 Portable Infrared Calibrator Our portable IR calibrators provide stable blackbody targets for calibrating noncontact IR thermometers from –30°C to 500°C P000315 Temperature Calibrators 0 VND Quantity: 1 Cái


  •  
  • Fluke 9132/9133 Portable Infrared Calibrator

  • Post on 23-09-2015 12:18:08 AM - 1729 Views
  • Price: Contact

  • Our portable IR calibrators provide stable blackbody targets for calibrating noncontact IR thermometers from –30°C to 500°C


Quantity
  • Precision when you need it for infrared temperature calibration

    • Certify IR pyrometers from –30°C to 500°C (–22°F to 932°F)
    • Large 57 mm (2.25 in) blackbody target
    • RTD reference well for contact temperature measurement
    • Small, compact design

    Whether you’re using in-line or handheld infrared pyrometers, you need good calibration standards to verify their accuracy. Our portable IR calibrators provide stable blackbody targets for calibrating noncontact IR thermometers from –30°C to 500°C.

    These units feature a temperature controlled measurement surface with a diameter of 2.25" (57 mm). The target temperature can be controlled in set-point increments of 0.1° from –30°C to 500°C and a well is located directly behind the blackbody surface for contact calibration.

Specifications 9132 9133
Temperature range 50°C to 500°C
(122°F to 932°F)
–30°C to 150°C at 23°C ambient
(–22°F to 302°F at 73°F ambient)
Accuracy ±0.5°C at 100°C
(±0.9°F at 212°F)
±0.8°C at 500°C
(±1.4°F at 932°F)
±0.4°C (±0.72°F)
Stability ±0.1°C at 100°C
(±0.18°F at 212°F)
±0.3°C at 500°C
(±0.54°F at 932°F)
±0.1°C (±0.18°F)
Target size 57 mm (2.25 in) 57 mm (2.25 in)
Target emissivity 0.95 (±0.02 from 8 to 14 mm) 0.95 (±0.02 from 8 to 14 mm)
Resolution 0.1° 0.1°
Heating time 30 minutes (50°C to 500°C) 15 minutes (25°C to 150°C)
Cooling time 30 minutes (500°C to 100°C) 15 minutes (25°C to –20°C)
Computer interface RS-232 I/O included with 9930 Interface-it software
Power 115 V AC (±10%), 3 A or
230 V AC (±10%), 1.5 A,
switchable, 50/60 Hz, 340 W
115 V AC (±10%), 1.5 A, or
230 V AC (±10%), 1.0 A,
switchable, 50/60 Hz, 200 W
Size (H x W x D) 102 x 152 x 178 mm
(4 x 6 x 7 in )
152 x 286 x 267 mm
(6 x 11.25 x 10.5 in)
Weight 1.8 kg (4 lb) 4.6 kg (10 lb)
NIST-traceable contact calibration Data at 50°C, 100°C, 200°C, 250°C, 300°C, 400°C, and 500°C Data at –30°C, 0°C, 25°C, 75°C, 100°C, 125°C, and 150°C
     

 