Fluke 725 Multifunction Process Calibrator Fluke 725 Multifunction Process Calibrator Fluke multifunction calibration tools designed to calibrate almost anything. These calibration tools source and measure almost all process parameters. P000272 Temperature Calibrators 0 VND Quantity: 1 Cái


  •  
  • Fluke 725 Multifunction Process Calibrator

  • Post on 23-09-2015 10:31:07 AM - 1038 Views
  • Price: Contact

  • Fluke multifunction calibration tools designed to calibrate almost anything. These calibration tools source and measure almost all process parameters.


Quantity
  • “Simply” Powerful!

    Take along the Fluke 725 Multifunction Process Calibrator, and you're equipped to test and calibrate almost any process parameter. Measure and source mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure, using optional pressure modules.

    From the moment you pick it up, the Fluke 725 is ready to perform. Its simple controls, without menus, make operation easy.

    Want more precision, pulse sourcing, totalizing and more? Consider the Fluke 726 Precision Multifunction Calibrator.

    Need an intrinsically safe rating in your calibrator? Consider the Fluke 725Ex Intrinsically Safe Multifunction Process Calibrator.

    Want documenting and HART communication built into your calibrator? Consider the Fluke 754 Documenting Process Calibrator with HART.

    Measurement Accuracy
    Voltage DC 30.000 V 0.02% + 2 counts (upper display)
    30.000 V 0.02% + 2 counts (lower display)
    100.00 mV 0.02% + 2 counts
    -10.00 mV to 75.00 mV 0.025% + 1 count (via TC connector)
    Current DC 24.000 mA 0.02% + 2 counts
    Resistance 0.0 to 400.0 Ω 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire)
    401 to 1500 Ω 0.5 Ω (4-wire), 1 Ω (2- and 3-wire)
    1500 to 3200 Ω 1 Ω (4-wire), 1.5 Ω (2- and 3-wire)
    Frequency 2.0 to 1000.0 CPM 0.05% + 1 count
    1.0 to 1100.0 Hz 0.05% + 1 count
    1.00 to 10.00 kHz 0.05% + 1 count
    Sensitivity 1 V peak-to-peak-minimum
    Pressure Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
    Source Accuracy
    Voltage DC 100.00 mV 0.02% + 2 counts
    10.000 V 0.02% + 2 counts
    -10.00 mV to 75.00 mV 0.025% + 1 count (via TC connector)
    Current DC 24.000 mA (source) 0.02% + 2 counts
    24.000 mA (simulate) 0.02% + 2 counts
    Resistance 15.0 to 400.0 Ω 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA)
    401 to 1500 Ω 0.5 Ω (excitation current 0.05 to 0.8 mA)
    1500 to 3200 Ω 1 Ω (excitation current 0.05 to 0.4 mA)
    Frequency 2.0 to 1000.0 CPM 0.05%
    1.0 to 1100.0 Hz 0.05%
    1.00 to 10.00 kHz 0.25%
    Waveform 5 V p-p squarewave, -0.1 V offset
    RTDs and Thermocouples
    Measure accuracy NI-120 0.2°C
    PT-100 (385) 0.33°C
    PT-100 (393) 0.3°C
    PT-100 (JIS) 0.3°C
    PT-200 (385) 0.2°C
    PT-500 (385) 0.3°C
    PT-1000 (385) 0.2°C
    Resolution 0.1°C
    J 0.7°C
    K 0.8°C
    T 0.8°C
    E 0.7°C
    R 1.8°C
    S 1.5°C
    B 1.4°C
    L 0.7°C
    U 0.75°C
    N 0.9°C
    Resolution J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
    XK 0.6°C
    BP 1.2°C
    Source accuracy NI-120 0.2°C
    PT-100 (385) 0.33°C
    PT-100 (393) 0.3°C
    PT-100 (JIS) 0.3°C
    PT-200 (385) 0.2°C
    PT-500 (385) 0.3°C
    PT-1000 (385) 0.2°C
    Resolution 0.1°C
    Accuracy stated for 4-wire measurement.
    J 0.7°C
    K 0.8°C
    T 0.8°C
    E 0.7°C
    R 1.4°C
    S 1.5°C
    B 1.4°C
    L 0.7°C
    U 0.75°C
    N 0.9°C
    Resolution J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C
    XK 0.6°C
    BP 1.2°C
    Specifications
    Ramp functions Source functions Voltage, current, resistance, frequency, temperature
    Ramps Slow ramp, Fast ramp, 25% step-ramp
    Loop power function Voltage 24 V
    Accuracy 10%
    Maximum current 22 mA, short circuit protected
    Step functions Source functions Voltage, current, resistance, frequency, temperature
    Steps 25% of range, 100% of range
    Environmental Specifications
    Operating temperature -10°C to +55°C
    Storage temperature -20°C to 71°C
    Operating altitude 3000 m
    Safety Specifications
    Agency approvals EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992
    Mechanical and General Specifications
    Size 130 x 236 x 61 mm
    Weight 0.65 kg
    Batteries 4 AA alkaline batteries
    Battery replacement Separate battery compartment, accessable without breaking calibration seal
    Side port connections Pressure module connector, also used for remote real-time programming
     

 

  Reader Comments

You did not use the site, Click here to remain logged. Timeout: 60 second