Fluke 190-502 500 MHz ScopeMeter® Test Tool Fluke 190-502 500 MHz ScopeMeter® Test Tool 5 GS/s sampling rate, 500 MHz bandwidth with 2 input channels and DMM for electronic field service applications. P000101 Portable Oscilloscopes 0 VND Quantity: 1 Cái


  •  
  • Fluke 190-502 500 MHz ScopeMeter® Test Tool

  • Post on 22-09-2015 03:29:12 PM - 1124 Views
  • Price: Contact

  • 5 GS/s sampling rate, 500 MHz bandwidth with 2 input channels and DMM for electronic field service applications.


Quantity

Why choose the new 500 MHz two-channel ScopeMeter® test tool?

A faster sample rate and higher bandwidth means greater accuracy and clarity. The scope will capture and display unknown waveform shapes, amplitudes and any disturbances. In order to display at least the fifth harmonic component of a signal, a good rule of thumb is to select a scope with a bandwidth of at least five times the maximum clock rate of the device under test. The faster the sample interval, the more accurate and detailed the scope will display a signal edge (dV/dt) and peaks of any reflections or transients.

 

Specifications
Bandwidth 500 MHz
Number of channels 500 MHz: 2 channels
Real-time sample rate 5 GS
Inputs 2 scope plus DMM input
Independently floating isolated inputs Up to 1000 V CAT III/600 V CAT IV between inputs, references and ground
Timebase range 10 ns - 2 min/div
Input sensitivity 2 mV-100 V/div
Trigger types Connect-and-View™, Free Run, Single Shot, Edge, Delay, Dual Slope, Video, Video Line, Selectable pulse width, N-Cycle
Trigger source Any scope input channel, or external via DMM input
Glitch capture 8 ns
Scope measurements Cursor: 7
Automatic: 30
Maximum record length ScopeRecord mode: 30,000 pts
Scope mode: 10,000 pts per input
Persistence Digital persistence giving analog oscilloscope-like waveform decay
Waveform compare Waveform reference with automatic Pass/Fail testing
DMM Specification
Meter inputs (also used as External Trigger Input for the Oscilloscope Mode) 4 mm banana inputs, fully isolated from scope inputs and from scope ground
Maximum resolution 5000 counts
Measurements VDC, VAC rms, VAC + DC rms, Resistance, Continuity, Diode Test, Current (through clamp or shunt), Temperature °C or °F (using optional converter)
Memory  2 Channel
Screen + Setup: 30
Recording: 10
Display 153 mm full color LCD with fast update rate
Environmental Specifications
Operating temperature 0°C to 40°C Including Batteries
0°C to 50°C Excluding Batteries
Storage temperature -20°C to +60°C
Operating altitude Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V
Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
Safety Specifications
Electrical safety 1,000 V CAT III/600V CAT IV (EN61010-1)
Mechanical and General Specifications
Size 270 x 190 x 70 mm
Weight 2.2 kg
Warranty 3-years on main instrument, 1-year on accessories
Li-Ion battery BP290 2400 mAh Li-ion battery up to 4 hours included standard
Included Accessories
  VPS410 Voltage Probe Sets (one red, one blue)
TL175 TwistGuard™ safety designed Test Lead Set (red and black)
BC190 Battery Charger/mains Adapter
BP290 2400 mAh Li-ion Battery
Handstrap (affixed to instrument)
Hangstrap
Multi-Language User Manuals on CD-Rom
FlukeView ScopeMeter® demo package (restricted functionality)
USB Interface Cable
Warranty Three years on main instrument, one year on accessories
     

 