Fluke 424D Laser Distance Meter Fluke 424D Laser Distance Meter The Fluke 424D Laser Distance Meter - measures up to 100 m (330 feet). Includes tilt sensor for hard-to-reach measurements, corner angle feature and compass. P000027 Laser Distance Meters 0 VND Quantity: 1 Cái


  •  
  • Fluke 424D Laser Distance Meter

  • Post on 22-09-2015 01:47:08 PM - 1148 Views
  • Price: Contact

  • The Fluke 424D Laser Distance Meter - measures up to 100 m (330 feet). Includes tilt sensor for hard-to-reach measurements, corner angle feature and compass.


Quantity
The Fluke 424D is our most sophisticated laser distance meter packed with versatile features to save you more time in more situations. It extends your measurement reach to 100 meters (330 feet). It offers a bigger, 4-line display, a built-in compass, and a 180º inclination sensor for leveling and height tracking.
 
Distance Measurement
Typical measuring tolerance 1 ±1.0 mm 3
Maximum measuring tolerance 2 ±2.0 mm 3
Range At Leica Target Plate GZM26 100 m / 330 ft
Typical range 1 80 m / 260 ft
Range at unfavorable condition 4 60 m / 195 ft
Smallest unit displayed 6 / 30 / 60 mm (10 / 50 / 100 m)
Ø Laser point at distances 6 / 30 / 60 mm (10 / 50 / 100 m)
Tilt Measurement
Measuring tolerance to laser beam 5 ±0.2°
Measuring tolerance to housing 5 ±0.2°
Range 360°
General
Laser cass 2
Laser type 635 nm, < 1 mW
Protection class IP54
Automatic laser off After 90 seconds
Automatic power off After 180 seconds
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 5,000 measurements
Size (L x W x D) 127 x 56 x 33 mm
Weight (with batteries) 158 g
Temperature range Storage operation -25°C to +70°C (-13°F to +158°F)
-10°C to +50°C (14°F to +122°F)
Calibration cycle Tilt and compass
Maximum altitude 3000 m
Maximum relative humidity 85% at 20°F to 120°F (-7°C to 50°C)
Safety IEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II)
EMC EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010
1. Applies for 100% target reflectivity (white painted wall), low background illumination, 25°C.
2. Applies for 10 to 500% target reflectivity, high background illumination, -10°C to +50°C.
3. Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
4. Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux.
5. After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.
     

 