Fluke 414D Laser Distance Meter Fluke 414D Laser Distance Meter The Fluke 414D laser distance meter – measures up to 50 meters (165 ft). Fast & easy to use, improves accuracy, reduces measurement errors. Saving time & money. P000021 Laser Distance Meters 0 VND Quantity: 1 Cái


  •  
  • Fluke 414D Laser Distance Meter

  • Post on 22-09-2015 01:41:07 PM - 863 Views
  • Price: Contact

  • The Fluke 414D laser distance meter – measures up to 50 meters (165 ft). Fast & easy to use, improves accuracy, reduces measurement errors. Saving time & money.


Quantity
Put the Fluke 414D on your tool belt and reach beyond the common tape measure. Measures up to 50 meters (165 ft). This professional-grade laser distance meter is fast and easy to use, improving accuracy and reducing measurement errors. You’ll save time and money at every step.
 
Distance Measurement
Typical measuring tolerance 1 ±2.0 mm 3
Maximum measuring tolerance 2 ±3.0 mm 3
Range At Leica Target Plate GZM26 50 m / 165 ft
Typical range 1 40 m / 130 ft
Range at unfavorable condition 4 35 m / 115 ft
Smallest unit displayed 1 mm / 1/16 in
Ø Laser point at distances 6 / 30 / 60 mm (10 / 50 / 100 m)
Tilt Measurement
Measuring tolerance to laser beam 5 No
Measuring tolerance to housing 5 No
Range No
General
Laser class 2
Laser type 635 nm, < 1 mW
Protection class IP40
Automatic laser off After 90 seconds
Automatic power off After 180 seconds
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 3,000 measurements
Size (L x W x D) 116 x 53 x 33 mm
Weight (with batteries) 113 g
Temperature range
Storage operation
-25°C to +70°C (-13°F to +158°F)
0°C to +40°C (32°F to +104°F)
Calibration cycle Not applicable
Maximum altitude 3000 m
Maximum relative humidity 85% at 20°F to 120°F (-7°C to 50°C)
Safety IEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II)
EMC EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010
1. Applies for 100% target reflectivity (white painted wall), low background illumination, 25°C.
2. Applies for 10 to 500% target reflectivity, high background illumination, -10°C to +50°C.
3. Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
4. Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux.
5. After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.
     

 

  Reader Comments

Products in this Category
You did not use the site, Click here to remain logged. Timeout: 60 second