Designed to Identify Complex Signal Problems Fast

When productivity is on the line and you need to solve problems fast, the Fluke 87V delivers the accuracy and advanced troubleshooting capabilities you need. Designed specifically to handle complex signals, the 87V industrial multimeter, allows you to gain productivity by taking the guesswork out of drive system troubleshooting even in loud, high energy, and high altitude locations.

  • Accurate frequency measurements on adjustable speed drives (ASD) due to Fluke-designed low-pass filter
  • Built-in thermometer allows temperature measurements without a separate thermometer
  • Peak Min/Max allows capture of intermittents as fast 250 µS
  • Dual display resolution – 6000 or 20,000 counts – lets you see small changes in displayed readings
  • CAT III 1000V, CAT IV 600V safety rated
  • Designed and built in the U.S.A.
  • Lifetime warranty

The Fluke 87V – Just One of Fluke's Trusted Tools

Fluke builds the most trusted tools in the world and that means more than just the Fluke 87V. If you work with HVAC equipment, need a small meter for small spaces or work in the electrical installer's and repairman's world, check out the full family of Fluke digital multimeters.

 

Specifications
Voltage DC Maximum voltage 1000 V
Accuracy ±(0.05% + 1)
Maximum resolution 10 µV
Voltage AC Maximum voltage 1000 V
Accuracy ±(0.7% + 2) True RMS
AC bandwidth 20 kHz with low pass filter; 3 db @ 1 kHz
Maximum resolution 0.1 mV
Current DC Maximum amps 10 A (20 A for 30 seconds maximum)
Amps accuracy ±(0.2% + 2)
Maximum resolution 0.01 µA
Current AC Maximum amps 10 A (20 A for 30 seconds maximum)
Amps accuracy ±(1.0% + 2) True RMS
Maximum resolution 0.1 µA
Resistance Maximum resistance 50 MΩ
Accuracy ±(0.2% + 1)
Maximum resolution 0.1 Ω
Capacitance Maximum capacitance 9,999 µF
accuracy ±(1% + 2)
Maximum resolution 0.01 nF
Frequency Maximum frequency 200 kHz
Accuracy ±(0.005% + 1)
Maximum resolution 0.01 Hz
Duty cycle Maximum duty cycle 99.9%
Accuracy ±(0.2% per khz + 0.1%)
Maximum resolution 0.1%
Temperature measurement –200.0°C – 1090°C
–328.0°F – 1994.0°F
excluding probe
80 BK temperature probe –40.0°C – 260°C
–40.0°F – 500°F, 2.2°C or 2% whichever is greater
Conductance Maximum conductance 60.00 nS
Accuracy ±(1.0% + 10)
Maximum resolution 0.01 nS
Diode Range 3 V
Resolution 1 mV
Accuracy ±(2% + 1)
Duty cycle range Accuracy Within ±(0.2% per kHz + 0.1%)
Environmental Specifications
Operating temperature –20°C to + 55°C
Storage temperature –40°C to + 60°C
Humidity (without condensation) 0% – 90% (0°C – 35°C)
0% – 70% (35°C – 55°C)
Operating Altitude 2000 m
Safety Specifications
Overvoltage category EN 61010–1 to 1000 V CAT III, 600V CAT IV
Agency approvals UL, CSA, TÜV, VDE listed
Mechanical and General Specifications
Size 201 x 98 x 52 mm (with holster)
Weight 355 g
624 g – with holster
Display Digital 6000 counts updates 4/sec.
19,999 counts in high–resolution mode
Analog 32 segments, updates 40/sec
Frequency 19,999 counts, updates 3/sec at > 10 Hz
Warranty Lifetime
Battery Life Alkaline ~400 hours typical, without backlight
Shock 1 Meter drop per IEC 61010–1:2001
Vibration Per MIL–PRF–28800 for a Class 2 instrument
     

 